Document MB8eR4LnOajJ1ga9GbBOr1Q7
Air Conditioning E^^fir<ld
Chicago Steel Furnace Co.
9326 S. Anthony Ave., Chicago 17,111.
Manufacturers and Designers Artcraft Heating & Air Conditioning Equipment
DIRECT-FIRED SPACE HEATERS
350,000 Btu to 2,000,000 Btu
UNIFORM AIR DELIVERY
BLOWERS--Three standard up-blast discharge, multi-vane Blowers, each in dividually powered, are provided to sup ply the correct amount of air to properly cool the Heat Exchanger. Individuallydriven Blowers are used because of the great flexibility of operation obtainable. Uniform bonnet temperature niay be enjoyed by the simple expediency, of in creasing or reducing the amount of air driven around any particular section of the Heat Exchanger.
Performance Data Direct Fired Model A Units
MODEL
OUTPUT BTU
AIR DEL. CFM
350-A
500-A 750-A
1000-A 1250-A
1500-A 2000-A
350,000 3000-4200 500,000 6000-7800
750,000 8200-0600 1,000,000 12500-15500 1,250,000 15000-17500
1,500,000 17500-21000 2,000,000 21000-24000
L
72 92 100 114 124 128 144
W
.36 42 50 54 56 62 66
H
84 90 99 110 1)4 115 125
ARTCRAFT SUSPENDED UNITS
Ratings and Specifications Suspended Units
MODEL
OUTPUT AIR DEL. BTU CFM-|"S.P.
L
WH
75-8 75-SL 100-8 150-8 200*8 250-8 350-8 400-8 500-8 750-8
85.000 800-1000 63 24 34 85,000 800-1000 78 22 22 100,000 1000-1600 76 24 34 150,000 1200-2000 79 31 36 200,000 2200-2600 86 31 40 250,000 2400-3200 90 35 42 350,000 3000-4200 104 38 53
400.000 4200-5200 107 40 53 600,000 4600-6200 114 45 62 750,000 8200-0600 146 52 66
1146
Factory Installation Modd tOQS-M
Air Conditioning BtoS^ted'lteSS.'nnit Heaters
Lee Corporation
1001 Tatnall Street, Wilmington, Delaware
Manufacturers and Designers of Complete Line of Industrial and Commercial Warm Air Heaters
Representatives in all Principal Cities Exclusive Representation to the Railroads: Railroad Supply and Equipment, Inc., First Federal Bide.. Scranton 3, Pa. In Canada: Comstock Lee Heating Division. Canadian' Comstock Company. 206 Laird Drive north.
Leaside. Toronto. Canada
Lee Heater Number
Output Capacity (Btu per hr) Total Heating Surface in sq ft Cu ft of Airper Min. (Approx.)* ' Fan Motor HP
External Static Pressure (Std.) Maximum External Static Press
Available for Duct Work (Larger Motor {Required) Temperature Rise (Degree F) Fuel Consumption** A-cu ft Gas per`hr (App.) B-gal Oil per hr (Approx.) Shipping Weight (Approx.) Lbs Refractory Comb. Chamber
Stainless Steel Comb. Chamber
LEE HEAVY DUTY HEATERS
LEE HEATERS have been in continuous operation since 1918. Lee Heater in stallations have been made in most of the States of the United States;, in Canada, Alaska, Yukon Territory, Northwest Territory, Labrador, Iceland, Norway, Mexico and South America. Firing Equipment manufactured spe cially for us by leading Companies with International service organization. There is a Service man near you if and when you require assistance. In addi tion Lee maintains a competent field serving staff. Replacement and Spare Parts Service is maintained. Most items are carried in stock.
300
300,000 92
3500
u1
I-
400
400,000 106 4500
r1*
I-
500
500,000 126 6000
2u
GOO
600.000 202 7000
3rr
750
750.000 235 8500 5
I-
79
380 2.6
3000 2100
82"
500 3.5
3100 2200
77
630 4.3
3300 2400
79
750 5.2
4500 4000
82
940 6.5
4700 4200
Lee Heater Number
Output Capacity (Btu per hr) Total Heating Surface in sq ft ' Cu ft of Air Der min. (Anorox.)* Fan Motor hp External Static Pressure (Std.) Maximum External Static Press.
Available for Duct Work (Larger Motor Required) Temperature Rise (Degree F) Fuel Consumption** A-cu ft Gas per hr. (App.) B-gal Oil per hr. (Approx.) Shipping Weight (Approx.) Lbs Refractory Comb. Chamber Stainless Steel Comb. Chamber
1,000
1,000,000 278
11,500 5 i1'
1250
1,250,000 333
r14,000 I-
1500
1,500,000 375
17,000 10
V
V
1750
1,750,000 423
20,000 15
VI'
2000
2,000,000 470
22,000 15
V
80
1250 8.6
6000 5200
83
1560 10.8
6300 5500
82
1880 13.0
7500 6200 .
81*
2190 15.0
8600 7400
84
2500 17.2
9800 8600
* Based on Standard Air at 70 F Free Delivery. , ** Fuel Consumption Based on 1000 Btn per cu ft Gas, 146,000 Btu per Gal Oil, and on 80 per cent Effiaency for thf heater.
1147